Earthquake-resistant houses rely on details: confining columns, 135° stirrup hooks, wall anchors and concrete quality, per Indonesia's 2024 PUPR guide.

27 November 2026 · 5 min read · Stadin

Key points

  • Indonesia's PUPR guide limits wall panels to 9 m², so confining columns are at most 3 m apart.
  • Stirrups need 135° hooks, and column bars must be anchored into tie and ring beams.
  • Multi-storey houses, basements and soft ground still need an engineer's calculations.

Indonesia sits in an active seismic region, and much of the damage after an earthquake is to houses built without any structural design. The good news is that earthquake-resistant houses do not have to be expensive. What matters most are details that are often treated as minor on site: confining columns, connections, anchors and concrete quality.

This article summarises those details with reference to the Buku Saku Petunjuk Konstruksi Bangunan Sederhana (pocket guide to simple building construction) published by the Directorate General of Human Settlements, Ministry of Public Works and Housing, in 2024.

Basic principles of earthquake-resistant houses

The Ministry's pocket guide lists four principles for earthquake-resistant buildings:

  1. Good-quality materials.
  2. Structural elements that are present and correctly sized.
  3. All main structural elements properly connected.
  4. Good workmanship.

The guide also stresses that every element must act as one unit. Foundation, tie beam, columns, ring beam and roof frame should all be tied together, so that when the ground shakes the house moves as one box rather than as separate wall panels falling away one by one.

Note that the guide is written for simple single-storey houses. Houses with two or more storeys, a basement, or soft ground below need structural calculations by an engineer.

Confining columns and wall area

Brick walls in a simple house are not designed to carry load. To stop them falling out of plane during an earthquake, they need a frame of small reinforced concrete columns (kolom praktis), tie beams and ring beams.

The guide limits wall panels to a maximum of 9 m², so columns are no more than 3 m apart. Common mistakes:

  • Leaving out columns at corners or wall junctions because "the wall is already there".
  • Long walls in garages or living rooms with no column in the middle.
  • Large door and window openings without a concrete frame around them.

Beam-column joints: the most overlooked detail

Many houses fail badly not because their columns are too small, but because the joints come apart. The guide sets out several connection details:

DetailGuide requirement
Stirrup endsBent at 135°, at least 5 cm long
Column bars into tie and ring beamsLap length at least 40 bar diameters
Stirrup spacing in beams and columns15 cm

A stirrup with a 90° hook opens easily once the corner concrete cracks, leaving the main bars unrestrained. A 135° hook that returns into the concrete core is much harder to pull out.

Column bars must also be properly anchored into the tie beam below and the ring beam above. A column whose bars simply stop at the beam face is a classic weak point.

Tip: Before each pour, take close-up photos of every column-to-beam junction. Once the concrete is cast, these details cannot be checked without breaking it out.

Anchors: tying walls, foundations and roofs together

Anchors are steel bars that connect elements of different materials. The guide specifies:

  • Anchors between the stone foundation and the tie beam at no more than 1 m centres.
  • Anchors between columns and brick walls every 6 brick courses, 10 mm in diameter and at least 40 cm long.
  • Gable walls under the roof anchored in the same way.
  • Roof trusses fixed to the ring beam with anchors or bolts of at least 10 mm diameter.

Tall, heavy brick gables are among the first parts of a house to collapse in an earthquake. The guide recommends lightweight materials such as timber boards or GRC for gables. Where brick is used, the gable needs a concrete frame and anchors.

Concrete quality and workmanship

Good detailing does little if the concrete is honeycombed. For simple houses the guide uses a mix of 1 cement : 2 sand : 3 gravel, with water at about half the cement quantity, gravel no larger than 20 mm, and cement complying with SNI. On site:

  • Do not add extra water to make the mix "easier to pour"; excess water reduces strength.
  • Keep formwork tight so cement paste does not leak out.
  • The guide recommends casting columns in 1 m lifts and compacting each lift to avoid voids.
  • Maintain the concrete cover so the reinforcement does not corrode.

If you want to understand the condition of an existing house, cracks in columns and beams are a useful first clue. See Hairline vs Structural Cracks.

When a house needs an engineer

The simple-building guide is a minimum, not a substitute for design. Bring in a structural engineer when:

  • The house has more than one storey, or you may add a floor later.
  • There is a basement, a raised swimming pool or long spans.
  • The ground is soft, filled or on a slope.
  • The layout is irregular, for example with many cantilevers or walls that do not continue down to the foundation.

For houses with a basement and pool, see our structural and foundation tips. Examples of houses designed by Stadin are on the residential page.

Conclusion

An earthquake-resistant house is built from consistent details: confining columns in the right places, stirrups with 135° hooks, properly anchored bars, anchors at every wall junction and well-made concrete. These details cost little when planned from the start, but a great deal when repaired after an earthquake. Any multi-storey house, or one on difficult ground, still needs calculation by a competent engineer.

Planning a multi-storey home? Talk to Stadin about the structural design of your house.

This article provides general information. Every project still needs to be analysed and calculated by a competent structural or geotechnical engineer, in line with the applicable SNI codes and regulations.

Contact

Start your project

Send us your architectural drawings or project brief. Our engineers will get back to you with scope, schedule and fee.