Key points
- Shallow excavations in good ground can use soldier piles; deep excavations need rigid walls.
- Contiguous piles are not watertight, secant piles are better, and diaphragm walls have the fewest joints.
- The final choice depends on soil data, excavation depth and neighbouring buildings.
Every basement starts with an excavation, and every deep excavation needs a wall that holds back the surrounding soil and groundwater. The choice of basement retaining wall affects cost, programme, leakage risk and the safety of neighbouring buildings. This article compares four systems commonly used on buildings: soldier piles, contiguous piles, secant piles and diaphragm walls.
The wider challenges of basements in soft ground are covered in Basements in Jakarta's Soft Ground. Here we focus on how each wall works and how to choose.
Flexible vs rigid walls
Retaining walls fall into two broad groups:
- Flexible walls, such as sheet piles and soldier piles. Lighter and quicker to install, but they deform more.
- Rigid walls, such as contiguous piles, secant piles and diaphragm walls. Used for deep excavations because they limit ground movement better.
The article Damage Control for Deep Excavations in STRUCTURE magazine (2021) notes that flexible walls suit excavations that are not too deep, while deep excavations generally use rigid walls.
Soldier piles: economical in good ground
A soldier pile wall consists of piles (steel sections or bored piles) at regular spacing, with the gaps closed by timber, panels or sprayed concrete (lagging) as excavation proceeds.
Its strengths are cost and speed. Its weaknesses are water and soft soil: lagging goes in piece by piece, and gaps between piles and lagging can let fine soil wash out. The system therefore suits good ground, a low water table and excavations that are not too deep.
Contiguous piles: stiff, but not watertight
A contiguous pile wall is a row of closely spaced bored piles that do not cut into each other. It is stiff enough to retain soil, but the small gaps between piles mean it is not watertight. In wet ground those gaps must be sealed with additional grouting or a lining wall.
It suits cohesive ground (reasonably stiff clay) where water inflow is not the main concern.
Secant piles: interlocking piles
A secant pile wall is built by boring alternate primary piles first, then boring secondary piles that cut into the primaries on either side. The result is a continuous wall that is far more watertight than a contiguous wall. The variants are:
| Type | Feature | Watertightness |
|---|---|---|
| Hard/soft | Primary piles of soft cement-bentonite, usually unreinforced | Generally not fully watertight |
| Hard/firm | Primary piles of weak-mix concrete | Depends on design; permanent use may need a lining |
| Hard/hard | Reinforced concrete primary and secondary piles | High; an alternative to a diaphragm wall |
Secant piles can be installed in difficult ground and where headroom is low. Their limits are holding vertical tolerance on deep piles and achieving fully watertight joints. They also cost more than sheet piles.
Diaphragm walls: for the deepest excavations
A diaphragm wall (D-wall) is built panel by panel. A narrow trench is excavated between two guide walls and supported by bentonite slurry so it does not collapse, then a reinforcement cage is lowered in and concrete is placed by tremie. Joints between panels carry a waterstop.
Its main advantages:
- Very stiff, and can be designed to carry high structural loads.
- Fewer joints, so better watertightness than a secant wall.
- Can also serve as the permanent basement wall, and is often combined with top-down construction.
However, a D-wall is expensive and needs specialist equipment. Its watertightness also depends on workmanship: guide walls, slurry quality, panel size and waterstop installation. Water can seep through panel joints below the end of the waterstop, or beneath the toe of the wall.
Tip: Decide early whether the retaining wall will also be the permanent basement wall. That decision changes the wall thickness, the connection details to the slabs and how seepage is handled.
How to choose: questions to answer
No system is always best. The choice depends on a few questions:
- How deep is the excavation? The deeper it is, the stiffer the wall needs to be.
- What are the soil and groundwater conditions? Only a site soil investigation can answer this.
- How close are neighbouring buildings? Nearby structures demand small deformations and groundwater control to avoid settlement.
- Will the wall form part of the permanent basement?
- How much working space is there? Tight urban sites limit the equipment that can get in.
In Indonesia, the design of excavations and retaining walls follows SNI 8460:2017 on geotechnical design requirements, and every option must be backed by calculations of stability, deformation and seepage.
Basements in Stadin projects
Several buildings with Stadin-designed structures have multi-level basements in Jakarta on bored pile foundations, including The Southgate Residence (3 basements), Safa-Marwa Tower (4 basements) and 18 Office Park (4 basements).
Conclusion
Soldier piles are economical for shallow excavations in good ground, contiguous piles are stiff but not watertight, secant piles offer better watertightness, and diaphragm walls are the choice for the deepest excavations or permanent basement walls. The final decision always depends on soil data, excavation depth and the surroundings, so it needs calculation by a competent geotechnical engineer.
Planning a basement? Discuss retaining wall options with Stadin's geotechnical and foundation team.
This article provides general information. Every project still needs to be analysed and calculated by a competent structural or geotechnical engineer, in line with the applicable SNI codes and regulations.
Sources
- Damage Control for Deep Excavations (STRUCTURE magazine, 2021)
- Secant pile wall (Designing Buildings Wiki)
- Retaining Walls (Balfour Beatty)
- Data proyek: company profile PT. Stadin Strukturindo Konsultan (2026)