Key points
- On long-span roofs, self-weight, deflection and wind uplift often govern more than strength alone.
- Steel trusses are the most common and easiest to calculate, but rely on bracing for sideways stability.
- Space frames spread load over many members working in tension or compression, suiting large areas and free forms.
- Membranes carry tension only; PTFE and PVC differ in lifespan, fire performance and cost.

Stadiums, multi-purpose halls, railway stations and exhibition buildings share one requirement: a large space with no columns in the middle. That calls for a long-span roof, a roof system that carries load between supports placed far apart. This article explains the three systems used most often for long-span roofs (steel trusses, space frames and membrane structures) and what building owners should weigh before choosing one.
Why long-span roofs behave differently
In an office or a house, columns are close together, so beams and roof trusses can stay simple. Once the distance between supports grows, several things change at once:
- Self-weight takes over. The longer the span, the more of the structure's strength is used just to carry itself. Long-span roofs therefore aim to be as light as possible.
- Deflection and vibration govern. A roof can be strong enough yet sag too much, causing problems for gutters, roof sheeting and ceilings.
- Wind can lift the roof. A large, light roof receives high wind suction (uplift). In Indonesia, wind loads are calculated with SNI 1727:2020, which adopts the American standard ASCE 7-16.
- Connections and erection drive cost. Large members must be lifted and assembled at height, so the structural design and construction method have to be developed together.
Steel trusses: the most common choice
A steel truss is a set of steel members arranged in triangles within one plane. Trusses are placed side by side and tied together with purlins and wind bracing.
Advantages:
- Their behaviour is easy to understand and calculate, so they suit projects of many sizes.
- Materials and skilled erectors are widely available.
- The shape is flexible: flat, pitched or curved.
The limitation is that a truss works mainly in its own plane. Sideways stability depends on bracing and purlins that must be designed carefully. For very long spans the truss depth also grows, which affects building height and appearance. Steel trusses are standard for warehouses and factories; see our comparison of steel and concrete for factories.
Space frames: light three-dimensional grids
A space frame is a rigid, lightweight truss-like structure made of interlocking struts in a three-dimensional geometric pattern. In the common system, tubular members meet at ball-shaped nodes. The MERO system, developed in Germany in 1943, is recorded as an early use of space trusses in architecture.
Because the structure is built from triangles in three dimensions, each member essentially carries only tension or compression, not bending. As a result:
- Load spreads over many members and many supports, so the roof can cover a large area with few interior supports.
- Components are repetitive and can be prefabricated, then assembled on site.
- The form can be flat, curved or free-form.
Space frames are widely used for sports halls, exhibition centres, stadiums, shopping malls and airports. An example from Stadin's work is the Halim High-Speed Railway Station case study, where a 3D box steel truss roof sits on a reinforced concrete structure.
Tip: A space frame can have thousands of nodes. Agree on fabrication tolerances, erection sequence and lifting method during design, not when the material arrives on site.
Membrane structures: fabric roofs working in tension
A membrane (fabric) structure is made of technical fabric, with or without a supporting frame. It belongs to the family of tensile structures: the membrane carries only tension, so its shape and prestress must be designed to keep the fabric from going slack or flapping.
Two materials are discussed most often:
| Material | Notes |
|---|---|
| PVC-coated polyester | Most widely used, more affordable, wider colour choice |
| PTFE-coated fibreglass | No significant creep, better fire performance, usually white |
One manufacturer states a design life of at least 50 years for PTFE and about 20–25 years for premium PVC. These are manufacturer figures, so always ask for technical data and a written warranty for the product you will use.
Membranes suit grandstand canopies, plazas, drop-off areas and buildings that need daylight without excessive heat. The downsides: they are so light that wind governs, the tension needs periodic checks, and their connections to steel frames or cables need special design.
How to choose a long-span roof system
No single system is always best. Engineers usually weigh:
- The use of the space below. Stadiums, mosques, stations and warehouses differ in clear height, acoustics and daylight needs.
- Architectural form. Free forms lean towards space frames or membranes; simple forms are often more efficient as steel trusses.
- Wind and seismic conditions on site. Light roofs are sensitive to wind, while heavy roofs add seismic load to columns and foundations.
- Erection method. Crane access, assembly space and the programme often decide the choice.
- Long-term maintenance. Steel needs corrosion protection; membranes need tension checks and cleaning.
For public buildings such as stadiums, for example the Ciracas Sports Stadium, the choice should also consider how easily the operator can maintain the roof over decades of use.
Conclusion
A long-span roof is not just a bigger roof. Self-weight, deflection, wind, connections and erection decide the design. Steel trusses win on simplicity, space frames on efficiency and freedom of form, and membranes on low weight and daylight. Every option must be calculated by a competent engineer for the actual project. Talk to us through Stadin's bridge and long-span structure design service.
This article provides general information. Every project still needs to be analysed and calculated by a competent structural or geotechnical engineer, in line with the applicable SNI codes and regulations.